Internal Cal Reset (Internal Calibration Reset) Event Number: 307 Event. Classification: Severe/Fatal Event Event Specific: Ch pair x Action: Replace Monitor Module immediately. Monitor TMR PPL Failed (Monitor TMR Proportional value Failed) Event Number: 310 Event. Classification: Potential Problem Action: Replace the Monitor Module. Monitor TMR PPL Passed (Monitor TMR Proportional value Passed) Event Number: 311 Event. Classification: Potential Problem Action: Replace the Monitor Module. Module Reboot Event Number: 320 Event. Classification: Typical Logged Event Action: No action required.